DGI SOLUTIONSPOWER · TRANSMISSION OHL SURVEY SHOWCASE
STEP 1
Select the tower and survey type
Context

This starts the survey against the correct tower and work type.

What to press

Choose a structure type and work type, then start the OHL survey.

What happens next

The correct tower-survey template loads and the tower drawing becomes the navigation.

YOU ARE NOW THE LINESMAN / SURVEYOR

Interactive Tower Survey

Work through the tower by tapping the actual part you are inspecting. Every required section, answer and evidence item is tracked before the survey can be submitted.

Assigned Asset

PWR-001 · Route 4YZ · ZG-1842 · 400 kV
ZG-1842Asset
4YZCircuit
400 kVVoltage
Offline ReadyField capture

ZG-1842 Survey

Tap a highlighted area of the tower or select a section below.

Suggested Screen-Recording Route

1 · Topee / Peak
Peak steelwork and earthwire / OPGW support.
2 · Faces AB / BC / CD / DA
Main legs, bracing, bolts, steelwork and corrosion.
3 · Top / Middle / Bottom Crossarms
Steelwork, fittings and left/right circuit identification.
4 · Insulator Strings
Arrangement, material, unit count, tower-end and conductor-end fittings.
5 · Conductor
Type/material, bundle, sag/height and visual condition.
6 · Tower Furniture
ACD, step bolts, signage, identification and fitted furniture.
7 · OPGW / Earthwire & Downleads
Clamps, dampers, routing, joint box and terminal arrangements.
8 · Foundations / Earthing / Spans
Leg bases, stubs, concrete, earth bonds, spacers and dampers.

Interactive Tower Navigation

TOPEE OPGW / EW TOP ARM MIDDLE ARM BOTTOM ARM INSINS CONDUCTORCONDUCTOR TOWER FACES FURNITURE DOWNLEADS FOUNDATIONS SPANS / FITTINGS

Survey Sections

Asset Identification & Site
Tower no., circuit plates, access, tower type
Incomplete
Topee / Peak
Peak steelwork and earthwire support
Incomplete
Faces AB / BC / CD / DA
Main legs, bracing, bolts, corrosion
Incomplete
Top Crossarm
Left/right circuit ID and fittings
Incomplete
Middle Crossarm
Left/right circuit ID and fittings
Incomplete
Bottom Crossarm
Left/right circuit ID and fittings
Incomplete
Insulator Strings & Fittings
Present, count, condition, tower end, conductor end
Incomplete
Conductor
Type/material, bundle, sag/level/height, visual condition
Incomplete
Tower Furniture
ACD, step bolts, plates, climbing/fitted furniture
Incomplete
Downleads
Terminal/gantry conductor routing and fittings
Incomplete
Earthwire / OPGW
Clamps, dampers, downlead, joint box where fitted
Incomplete
Spans / Spacers / Dampers
Adjacent span and conductor fittings
Incomplete
Legs / Foundations / Earthing
A/B/C/D bases, concrete, stubs, visible earth bonds
Incomplete
Submission blocked until every mandatory section has been completed.

Section

✓

Survey Complete

Structured asset record ready for DGI QA and authorised client release.
Asset
ZG-1842
Circuit / Voltage
4YZ · 400 kV
Structure Type
Work Type
Evidence
Mandatory fields · multiple photos · capture time · GPS · operative · asset reference